Description
The Reed R9910SD Indoor Air Quality Meter monitors up to three probes all at once, offering precise recordings with convenient features such as Data hold, Max/Min, and a backlit LCD display. Records can be manually recorded up to 99 readings or set to a desired sampling rate from 1 sec to 8 hours—without the need for software. The optional AC adapter and tripod allow for continuous long-term monitoring.
Features
- Measures oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), temperature and humidity
- Records up to 3 readings simultaneously
- User adjustable audible alarms
- User selectable unit of measure (°C or °F)
- Data hold and Max/Min functions
- Real-time data logger with integrated SD memory card
- User selectable sampling rate from 2 secs to 8 hrs
- Easy-to-read backlit LCD display
- Tripod mount for long-term monitoring
- Low battery indicator and auto shut off
Specifications
| Temperature | |
| Measuring Ranges | 32 to 122.0°F (0 to 50.0°C) Dew Point: -13.5 to 120.1°F (-25.3 to 48.9°C) Wet Bulb: -6.9 to 122.0°F (-21.6 to 50°C) | 
| Accuracy | ±1.5°F (±0.8°C) | 
| Resolution | 0.1°F/°C | 
| Humidity | |
| Measuring Ranges | 5 to 95%RH | 
| Accuracy | >70%RH: ±(3% rdg + 1%RH) <70%RH: ±3%RH | 
| Resolution | 0.1%RH | 
| CO2 | |
| Measuring Ranges | 0 to 4,000 ppm | 
| Accuracy | <999 ppm: ±40 ppm >1,000 ppm ≤3000 ppm: ±5% rdg >3,000 ppm: ±250 ppm | 
| Resolution | 1 ppm | 
| CO | |
| Measuring Ranges | 0 to 1,000 ppm | 
| Accuracy | ±(5% + 2 ppm) | 
| Resolution | 1 ppm | 
| O2 | |
| Measuring Ranges | 0 to 30% O2 | 
| Accuracy | ±(1% + 0.2% O2) | 
| Resolution | 0.10% | 
| General Specifications | |
| Alarm Threshold | <18% O2 | 
| Response Time | 1 second | 
| Display | 4-digit dual LCD | 
| Backlit Display | Yes | 
| Data Hold | Yes | 
| Min | Yes | 
| Max | Yes | 
| Datalogging Capabilities | Yes | 
| Real-Time Clock and Date Stamp | Yes | 
| Selectable Sampling Rate | Yes (1 second to 8 hours, 59 minutes and 59 seconds) | 
| External Memory | Yes, expandable up to 16GB with SD card (optional) | 
| Auto Shut-off | Yes (after 10 minutes/off) | 
| Kick Stand | Yes | 
| Tripod Mountable | Yes | 
| Low Battery Indicator | Yes | 
| Power Supply | 6 x AA Batteries or AC Adapter (optional) | 
| Data Output | Yes (RS-232) | 
| Product Certifications | CE | 
| Operating Temperature | 32 to 122°F (0 to 50°C) | 
| Storage Temperature | 14 to 140°F (-10 to 60°C) | 
| Operating Humidity Range | 10 to 85% | 
| Dimensions | Instrument: 7.0 x 2.7 x 1.8" (177 x 68 x 45mm) Humidity Probe Length: 7.8" (197mm) CO Probe Length: 5.9" (150mm) CO2 Probe Length: 7.5" (190mm) O2 Probe Length: 5.9" (150mm) | 
| Weight | 0.8lb (350g) | 
Applications
Environmental Monitoring in:- Schools
- Office buildings
- Greenhouses
- Factories
- Hotels
- Hospitals
- Areas where high levels of carbon dioxide are generated
Downloads
Included Items
 
                             - Data Logging Air Quality Meter
- Humidity Probe
- Carbon Monoxide Probe
- Carbon Dioxide Probe
- Oxygen Probe
- Hard Carrying Case
- Batteries

 
     
                        
          
                       
 