Search Results
-
Ergo Kit Carrying CaseProtective carrying case for ergonomic gauges and accessories. Features and Specifications Volume Capacity: 1451.5 cu in. Weight: 3.25 lbs. Recessed latch Molded Handles Padlock Tab 2 Layers of High-Density Convoluted Foam One layer is pluck foam Recessed Handle 2 Locking Points Dimensions Overall Length 16-3/4 in. Overall Width 14-1/2 in. Overall Depth...
-
Chatillon TD5 Mechanical DynamometerThe CHATILLON® TD5 Series mechanical dynamometer may be used as a weighing tensiometer or crane scale. This precision weighing instrument features an easy-to-read 5-inch (127 mm) dial face with shatter-resistant dial cover in a strong aluminum housing. Available with pound or kilogram dial face, the TD5 Series accuracy is better than 1%...
-
SPK-FMG-069A, Chatillon DFA DFT Series Force Gauge ChargerBattery Charger for Chatillon DFA and DFT series force gauges.
-
WT3004 Carrying CaseProvides storage space for the WT3-201 tester, optional ring terminal fixture, AC adapter, USB cable, and accessories.
-
Spare Canners Puncture ProbeSpare puncture probe/needle for JLW-Canners canning pressure gauge. Contact us to learn more about vacuum gauges
-
Pesola 8.004 Pressure Set Accessory for Macro-Line ScalesThis pressure set accessory will transform Macro-Line Scales into a pressure measuring instrument within 20 seconds. Included Items Pressure rod Ø 5 x 360 mm, with thread M5 x 5 mm at both ends 4 interchangeable fittings (M5) Handle Cap-nut (M8) to replace standard lower hook. Video
-
AC1002-1 Single Handle for Mark-10 Series 4, 5 and 7 Force GaugesDouble-handle grips for Series 4, Series 5, and Series 7 Force gauges. Used for mounting a force gauge in various applications, such as ergonomics testing, job task analysis, and muscle strength evaluation. Handles are included with Mark-10 ergonomics testing kits.
-
Reed R9905 Indoor Air Quality MeterThis data logging Indoor Air Quality (IAQ) Meter has the ability to record samples on internal memory and keep track of registered readings with a time and date stamp. The R9905 features a Nondispersive Infrared (NDIR) CO2 sensor for stable, accurate readings and the option to track live measurements via software. Features...
-
PG-CASE Carrying Case for B&L Pinch GaugesOptional storage case provides added protection for your B&L Engineering® Pinch Gauge during transportation and helps maintain calibration accuracy.Double-walled rigid plastic carrying case with foam insert molded to hold and protect your B&L Engineering Pinch Gauge.
-
Spare Rubber Gasket SealSpare rubber gasket for JLW-Canners canning pressure gauge.
-
Mark-10 AC1110, Mitutoyo SPC Cable (formerly 09-1164)Gauge to Mitutoyo SPC cable. The length of the cable is 6 ft. Compatible Instruments Force gauges: Series 7, 5, 4 Digital Indicators: 7i, 5i Torque gauges:, TT01, TT02, TT05, Wire pull tester: WT3-201(M)
-
Mark-10 AC1104, Serial Cable (formerly 09-1056)Serial cable, test stand controller to RS-232 DB9. The length of the cable is 10 ft. Compatible Instruments Test Stands: ESM301(L), ESMH-DC, TSFM500(H)-DC, ESMH-DC, TSTM(H)-DC
-
AC1079 Adjustable Angle Mount for G1109 FixtureThe AC1079 is an adjustable-angle mount that tilts the G1109 Peel fixture up to ±30°. AC1079 included Items G1109 + AC1079 Dimensions in Documents G1109 Data Sheet G1109 AC1078 AC1079 Manual
-
TSF001 Travel DisplayDigital travel display for TSF manual test stand. 6" [150 mm] travel, 0.0005" [0.01 mm] resolution, SPC output for automated data collection. Requires travel stops kit. For output of travel data to a PC, the following items are required: 09-1066 cable and MRS100A communication adapter. Note: continuous data output rate is...
-
ElectroSamson Hanging ScaleThis modern sharp looking scale offers all the qualities of a traditional hanging balance with the simplicity, convenience and accuracy of digital scale. Ideal foruse in a wide range of general applications from sports fishing, poultry weighing, seed and animal feed preparation, health & safety audits for safe lifting and toidentify used...
-
Chatillon SPK/CS2/0057 CS Touchscreen UpgradeUpgrade old CS225 and CS1100 touchscreens to new 2 in 1 laptop/touchscreen. Upgrading to the SPK/CS2/0057 2 in 1 laptop/touchscreen will provide faster start up, faster processor, and more memory. Includes brackets needed for mounting the touchscreen to the CS.
-
AHFG Pull HandlesPull handles for JL Series mechanical force gauges.
-
Magness Taylor Food Texture ProbesThese probes are designed for penetrating fruits, vegetables, and other foods, for determining puncture resistance and ripeness.Select from standard Magness Taylor diameter sizes of 5/16” and 7/16”, each with a flat and rounded end.A G1010-2 Jacobs chuck grip is required to mount a probe to a Mark-10 force sensor or force gauge. Features...
-
Reed R8008 Radiation MeterThe R8008 detects alpha, beta, gamma and X rays, offering user adjustable alarm limits. This portable radiation meter also is equipped with internal memory for storing up to 4000 data groupings and the capability to pair wirelessly with a PC over Bluetooth. Features Detects Alpha, Beta, Gamma, and X radiation Automatic selection of...
-
CBT/1400/00 USB Null Cable, RS232 Export from CS2 Test StandThis cable is used by the Chatillon CS2 test stand laptop console or CS test stand with tablet upgrade to communicate directly to a PC. Connections on the cable are USB-A on both ends. It can be used to export data using RS232 or used in controlling the test stand using...
-
Reed R3100, Digital Manometer 100 psiThe Reed R3100 digital manometer measures gauge and differential pressure up to 100 psi. Provides accurate measurements in 11 different units of measure and is capable of taking gauge and differential pressure. | Features Measures gauge and differential pressure up to 100psi 11 selectable units of measure: psi, inH2O, bar, mbar,...
-
Vice Grip Jaws For 01/44(49, 50, 51, 52...Vice grip jaws available with rubber, crosscut, wave, plain, v-notch, and diamond coated faces. Jaws are sold as a set (4 jaws). Jaws Highlighted jaws are models available online. All other models are available on request. Part # Description 01/4238 30mm x 30mm, Plain faces 01/4239 30mm x 30mm, Rubber faces 01/4240 30mm x 30mm,...
-
ESM003-1/-2/-3 Column Extension for ES30 Manual Test StandsColumn extensions increase the clearance between the force gauge and base (does not increase travel distance). This column extension is mounted between the base and the column on the ES30 Manual Test Stand. Available in 6", 12", and 24". ESM003-1: 6" Column extension ESM003-2: 12" Column extension ESM003-3: 24" Column...
-
AWT20-508223 Rubber SleeveProtective rubber sleeve, gray (recommended for outdoor applications).
-
Reed R8090 Sound Level CalibratorThis sound calibrator generates a stable acoustic signal at a controlled frequency and amplitude to verify the accuracy of your sound level meter. The R8090 is compatible with all 1/2" diameter microphones. Features Generates stable acoustic signal at a controlled frequency and amplitude to verify sound level meter accuracy Accommodates sound meters with...
-
SPK-FMG-HANDLE, Handle for LG Series Force GaugesDouble handle for LG Series mechanical force gauges.
-
Pesola 4.004 Pressure Set for Medio-Line ScalesWith this accessory all Medio-Line Scales up to max. 2500 g / 25 N can be easily transformed into pressure measuring instruments within seconds. Drag pointer for maximum load indication per measurement included. The lower suspension can be easily removed if not needed. Included Items Pressure rod Ø 1.7 x 290 mm, threaded M2...
-
Mark-10 TSTM-DC Motorized Torque Test StandThe TSTM-DC Advanced Motorized Torque Test Stand offers all the mechanical specifications of the TSTM motorized test stand, including standard 100 lbFin (11.5 Nm) torque capacity, versatile modular design, quick engagement and disengagement of samples, fixture mounting plate, stepper motor design that prevents speed variation with load, and more. A 200...
-
Mark-10 AC1112, Analog Cable (formerly 09-1166)Analog cable, gauge to dual banana plug. The length of the cable is 6 ft. Compatible Instruments Force gauges: Series 7, 5, 4 Digital Indicators: 7i, 5i Torque gauges:, TT01, TT02, TT05, Wire pull tester: WT3-201(M)
-
SPK-TCD-024 Cable from Console to TCD225, TCD1100 Test StandTCD Console to TCD Frame Communication Cable 26-pin.
-
Mark-10 MU100 Adapter Cable for Travel Display Data OutputFor converting Mitutoyo to USB. If using this to output travel data from a Mark-10 digital travel display to a PC, both the MU100 and the 09-1066 cable is needed.
-
AC1078 Adjustable Angle Pulley AdapterThe AC1078 Adjustable Angle Pulley Adapter is designed to be used with the G1109 Peel Test Fixture. This adapter uses an adjustable pulley to set the angle of pull, from 0° to 90°, while the working table remains horizontal. The horizontal orientation is suited for seal testing of filled containers,...
-
Mark-10 TSB003 Travel Stop for TSB100 Manual Test StandAdjustable travel stops for the TSB100 manual test stand.
-
Reed R9905-PROBE, Replacement Probe for Air Quality MeterReplacement Temperature and Humidity Probe for the REED R9905 Data Logging Indoor Air Quality Monitor.
-
ST001 Mounting BracketBench mounting bracket for TT02 Torque Tool Tester. Mounts the TT02 to a bench for horizontal or other orientations.
-
Reed R8050-KIT Sound Level Meter KitThis kit comes equipped with a rugged carrying case and the tools you need to conveniently calibrate your sound level meter in the field. The R8050-KIT includes the R8050 Sound Level Meter, the R8090 Sound Level Calibrator (SC-05), the R8888 Hard Carrying Case with Laser Etched Custom Foam Interior (specifically designed...
-
Reed R8085 Noise Dosimeter, Logs Personal Noise ExposureThis noise dosimeter has the ability to record sound levels (dB) and sound exposure (dose %) in order to determine an individual's sound exposure over an 8-hour period. The R8085 is a lightweight and compact Dosimeter designed to meet noise survey requirements established by OSHA (Occupational Safety and Health Administration) and...
-
SPK/CS/0010, CS Base Plate AssemblyBase Plate assembly that comes with the CS225, CS1100, CS2-225 and CS2-1100. Included Items Plate 2 Bolts 2 T-Slot Nuts
-
Mark-10 AC1105, Mitutoyo Travel Display Cable (formerly 09-1066)Cable, travel display to Mitutoyo SPC. The length of the cable is 6 ft. If outputting travel from a Mark-10 manual test stand display to a PC, the following cables will be needed. Travel display (Mitutoyo) <=> AC1105 cable, Mitutoyo <=> MU100 Compatible Instruments Mitutoyo travel display mounted to ES30, TSA750(H), TSB100, TSC1000(H),...
-
Mark-10 TSF Test Stand Column Extensions: 12", 24" & 48"This add-on for the TSF Manual test stand adds the lengths shown below to the column length. The price is based on the extension being added at time of purchase to the manual test stand. Model Length added to standard column SP-2735-12 Column extension, 12 in. / 305 mm SP-2735-24 Column...
-
Lloyd Video ExtensometerThe VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests. The VE1 extensometer offers high resolution measurement, simple preparations and an intuitive user interface.The video extensometer measures longitudinal strain...
-
AC1004 Mounting for an Indicator to a Manual Test StandMounting kit for Mark-10 digital indicators or Series TT03 torque gauges to a TS Series manual test stand. AC1004 is compatible with TSA750 / TSA750H TSB100 TSC1000 / TSC1000H TSF / TSFH TST / TSTH Typically used in combination with an AC1018 load cell mounting kit.
-
AC1002 Double Handle for Mark-10 Series 4, 5 and 7 Force GaugesDouble-handle grips for Series 4, Series 5, and Series 7 Force gauges. Used for mounting a force gauge in various applications, such as ergonomics testing, job task analysis, and muscle strength evaluation. Handles are included with Mark-10 ergonomics testing kits.
-
Reed R3030 Digital ManometerThe Reed R3030 digital manometer measures gauge and differential pressure up to 30 psi. Provides accurate measurements in 11 different units of measure and is capable of taking gauge and differential pressure. Internal memory of the Reed R3030 captures maximum and minimim measurements. | Features Measures gauge and differential pressure up...
-
TSC001, Travel Display for TSC1000Digital display can measure 6" [150 mm] of travel at 0.0005" [0.01 mm] resolution, has SPC output for automated data collection. For output of travel data to a PC, the following items are required: 09-1066 cable and MRS100A communication adapter. Note: continuous data output rate is limited to 2 Hz. Mounting hardware...
-
AWT25-501124 Mains power supplyMains Power supply, 100-240 VAC/5V to RS-232 for "Red" EDXtreme/Communicator II/Quick Check.
-
AC1074 Remote Emergency SwitchRemote emergency switchConvenient for when the standard emergency switch is inaccessible, for example if a safety shield is used. Includes an 8’ (2.4 m) cable, and plugs directly into the rear of the test stand. The standard, attached emergency switch remains operational while the remote switch is plugged in.
-
AWT05-509279 Data Export PackData export pack, includes all cables and interfaces to connect from the unit directly into a PC.
-
Dillon AP10 Series, 10" Dial Crane Scale DynamometerOriginally designed to measure the tension on telephone wires, the AP Dynamometer has proven to have limitless versatility as a tension and weight measuring instrument. It is used for such diverse jobs as suspended weighing, mounting cables for bridges, adjusting tension on guy wires, field testing chain and rope as well...
-
Mark-10 AC1113, Interface Cable for Setpoint & Overload (formerly 09-1180)Cable, set point / overload protection, gauge to test stand. The length of the cable is 28 in retracted. Compatible Instruments Series 7, 5, 4 instruments with ESM, TSFM500, ESMH, TSTM test stands
-
WFCOMP Complete Options PackageIncludes all optional functions for Mark-10 WT3-201M motorized wire pull tester.
-
Chatillon NC000855 Printer CableNC000855 Printer Cable Used to interface an RS232 9-Pin output to a 25-Pin Printer Input. | Specifications Connector: 25-pin printer male Connector: 9-pin RS232 female Cable Length: 10 ft